Siemens 3RW5056-6AB04 soft starter, 200-480V 171 A, 24V AC S SScrew terminals Analog output.
Siemens 3RW5056-6AB04 soft starter, 200-480V 171 A, 24V AC S SScrew terminals Analog output.
Manufacturer's article number
● of standard HMI module usable 3RW5980-0HS01
● of high feature HMI module usable 3RW5980-0HF00
● of communication module PROFINET standard usable 3RW5980-0CS00
● of communication module PROFIBUS usable 3RW5980-0CP00
● of communication module Modbus TCP usable 3RW5980-0CT00
● of communication module Modbus RTU usable 3RW5980-0CR00
● of communication module Ethernet/IP 3RW5980-0CE00
● of circuit breaker usable at 400 V 3VA2220-7MN32-0AA0; Type of assignment 1, Iq = 20 kA
● of circuit breaker usable at 500 V 3VA2220-7MN32-0AA0; Type of assignment 1, Iq = 20 kA
● of the gG fuse usable up to 690 V 3NA3244-6; Type of coordination 1, Iq = 65 kA
● of full range R fuse link for semiconductor protection usable up to 690V 3NE1 230-0; Type of coordination 2, Iq = 65 kA
● of back-up R fuse link for semiconductor protection usable up to 690V 3NE3 335; Type of coordination 2, Iq = 65 kA
● of line contactor usable up to 480 V 3RT1056
● of line contactor usable up to 690 V 3RT1064
General technical data
starting voltage [%] 30 ... 100 %
stopping voltage [%] 50 %; non-adjustable
start-up ramp time of soft starter 0 ... 20 s
ramp-down time of soft starter 0 ... 20 s
current limiting value [%] adjustable 130 ... 700 %
certificate of suitability
● CE marking Yes
● UL approval Yes
● CSA approval Yes
product component
● HMI-High Feature No
● is supported HMI-Standard Yes
● is supported HMI-High Feature Yes
product feature integrated bypass contact system Yes
number of controlled phases 2
buffering time in the event of power failure
● for main current circuit 100 ms
● for control circuit 100 ms
insulation voltage rated value 600V
degree of pollution 3, acc. to IEC 60947-4-2
impulse voltage rated value 6kV
blocking voltage of the thyristor maximum 1400V
service factor 1
surge voltage resistance rated value 6kV
maximum permissible voltage for protective separation
● between main and auxiliary circuit 600V
shock resistance 15 g / 11 ms, from 12 g / 11 ms with potential contact lifting
vibration resistance 15 mm to 6 Hz; 2g to 500Hz
utilization category according to IEC 60947-4-2 AC-53a
reference code according to IEC 81346-2 Q
Substance Prohibitance (Date) 09/23/2019
SVHC substance name:
Lead - 7439-92-1
Lead monoxide (lead oxide) - 1317-36-8
2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol - 79-94-7
2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one - 71868-10-5
6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol - 119-47-1
Weight 5.8 kg
product function
● ramp-up (soft starting) Yes
● ramp-down (soft stop) Yes
● Soft Torque Yes
● adjustable current limitation Yes
● pump ramp down Yes
● intrinsic device protection Yes
● motor overload protection Yes; Electronic motor overload protection
● evaluation of thermistor motor protection No
● auto-RESET Yes
● manual RESET Yes
● remote reset Yes; By turning off the control supply voltage
● communication function Yes
● operating measured value display Yes; Only in conjunction with special accessories
● error logbook Yes; Only in conjunction with special accessories
● via software parameterizable No
● via software configurable Yes
● PROFIenergy Yes; in connection with the PROFINET Standard communication module
● voltage ramp Yes
● torque control No
● analog output Yes; 4 ... 20 mA (default) / 0 ... 10 V (parameterizable with High Feature HMI)
Power Electronics
operational current
● at 40 °C rated value 171 A
● at 50 °C rated value 153 A
● at 60 °C rated value 141 A
operating voltage
● rated value 200 ... 480 V
relative negative tolerance of the operating voltage -15 %
relative positive tolerance of the operating voltage 10 %
operating power for 3-phase motors
● at 230 V at 40 °C rated value 45 kW
● at 400 V at 40 °C rated value 90 kW
Operating frequency 1 rated value 50 Hz
Operating frequency 2 rated value 60 Hz
relative negative tolerance of the operating frequency -10 %
relative positive tolerance of the operating frequency 10 %
adjustable motor current
● at rotary coding switch on switch position 1 81 A
● at rotary coding switch on switch position 2 87 A
● at rotary coding switch on switch position 3 93 A
● at rotary coding switch on switch position 4 99 A
● at rotary coding switch on switch position 5 105 A
● at rotary coding switch on switch position 6 111 A
● at rotary coding switch on switch position 7 117 A
● at rotary coding switch on switch position 8 123 A
● at rotary coding switch on switch position 9 129 A
● at rotary coding switch on switch position 10 135 A
● at rotary coding switch on switch position 11 141 A
● at rotary coding switch on switch position 12 147 A
● at rotary coding switch on switch position 13 153 A
● at rotary coding switch on switch position 14 159 A
● at rotary coding switch on switch position 15 165 A
● at rotary coding switch on switch position 16 171 A
● minimum 81 A
minimum load [%] 15 %; Relative to smallest settable Ie
power loss [W] for rated value of the current at AC
● at 40 °C after startup 29 W
● at 50 °C after startup 23 W
● at 60 °C after startup 20 W
power loss [W] at AC at current limitation 350 %
● at 40 °C during startup 1 751 W
● at 50 °C during startup 1 478 W
● at 60 °C during startup 1 308 W
Type of the motor protection: Electronic, tripping in the event of thermal overload of the motor.
Soft starter 3RW50 family products:
3RW5075-6AB15
3RW5072-2TB14
3RW5072-2TB15
3RW5072-6TB14
3RW5072-6TB15
3RW5073-2AB04
3RW5073-6TB14
3RW5073-6TB15
3RW5055-2TB04
3RW5055-6AB04
3RW5055-6AB05
3RW5055-6AB14
3RW5072-2AB14
3RW5072-2AB14
3RW5072-6AB05
3RW5073-2TB15
3RW5073-6AB04
3RW5073-6AB04
3RW5073-6AB04
3RW5073-6AB04
3RW5073-6AB05
3RW5072-2TB05
3RW5073-2TB04
3RW5073-2TB05
3RW5073-6TB04
3RW5074-2AB04
3RW5074-2AB05
3RW5074-2AB14
3RW5075-6AB04
3RW5075-6AB04
3RW5075-6AB05
3RW5076-2AB15
3RW5076-2TB04
3RW5076-2TB05
3RW5076-2TB05
3RW5076-6TB15
3RW5077-2AB04
3RW5077-2AB05
3RW5077-6AB04
3RW5077-6AB05
3RW5077-6AB14
3RW5074-6TB14
3RW5074-6TB15
3RW5074-6TB15
3RW5075-2AB04
3RW5056-6TB15
3RW5072-2AB15
3RW5072-2TB04
3RW5073-2AB05
3RW5073-2AB14
3RW5073-2AB15
3RW5073-2AB15
3RW5074-2AB15
3RW5074-2TB04
3RW5074-2TB05
3RW5074-6AB15
3RW5074-6TB04
3RW5074-6TB05
3RW5075-6AB14
3RW5075-6TB04
3RW5077-2TB05
3RW5077-2TB14
3RW5077-2TB15
3RW5055-2AB14
3RW5055-2AB15
3RW5055-6AB15
3RW5055-6TB04
3RW5055-6TB05
3RW5073-6TB05
3RW5073-2TB14
3RW5074-6AB14
3RW5077-6TB05
3RW5077-6TB14
3RW5077-6TB15
3RW5077-6TB15
3RW5072-2AB05
3RW5074-2TB14
3RW5074-2TB15
3RW5074-2TB15
3RW5074-6AB04
3RW5074-6AB04
3RW5072-6AB15
3RW5072-6TB04
3RW5072-6TB05
3RW5056-6TB04
3RW5072-2AB04
3RW5055-6TB15
3RW5056-2AB04
3RW5055-2TB15
3RW5055-6TB14
3RW5074-6AB05
3RW5055-2AB04
3RW5055-2AB05
3RW5056-2TB04
3RW5056-2TB05
3RW5056-2TB14
3RW5076-6TB04
3RW5076-6TB05
3RW5076-6TB14
3RW5055-2TB05
3RW5075-2TB15
3RW5076-2TB14
3RW5055-2TB14
3RW5056-2TB15
3RW5056-6AB04
3RW5056-6AB04
3RW5076-2TB15
3RW5077-2AB14
3RW5077-2AB15
3RW5077-2TB04
3RW5075-2AB05
3RW5075-2AB14
3RW5075-2AB15
3RW5076-2AB04
3RW5076-2AB05
3RW5076-2AB14
3RW5076-6AB04
3RW5076-6AB05
3RW5076-6AB14
3RW5076-6AB15
3RW5077-6AB15
3RW5077-6TB04
3RW5056-2AB05
3RW5075-2TB04
3RW5075-2TB05
3RW5075-2TB14
3RW5075-6TB05
3RW5075-6TB14
3RW5075-6TB15
3RW5072-6AB14
3RW5073-6AB14
3RW5073-6AB15
3RW5900-0CC00